Parameter | Mand | Type | Default | Constraints |
set | yes | e | ||
Input set containing spectroscopy or high-resolution timing data for
each CCD. | ||||
ccdset | yes | e | ||
This output set contains all collected data necessary for future analysis. Need write access. | ||||
minexposuretime | no | r | 0.001 | |
frame exposuretimes below this value are flagged as bad (sec) | ||||
withratecolumn | no | b | Yes | |
Add column with number of raw pixels per frame to EXPOSURE table | ||||
withmaxrawpixels | no | b | No | |
mark frames with more pixels above given level as bad | ||||
maxrawpixels | no | i | 9999 | |
frames with more pixels than this level are flagged bad | ||||
withmaxrawpixelrate | no | b | no | |
mark frames with pixelrate above given level bad | ||||
maxrawpixelrate | no | r | 9999. | 0. |
frames with a raw pixelrate above this level are flagged bad (pixels/sec) | ||||
processall | no | b | no | |
internally loop over all event lists of all exposures; this is
important for efficiency improvements of the HTR processing. | ||||
instrument | no | s | RGS1 | RGS1|RGS2 |
specify instrument for processall=true | ||||
Parameter | Mand | Type | Default | Constraints |
XMM-Newton SOC/SSC -- 2019-06-02