The Uncertainty command
can be used to estimate the uncertainties in the parameter values.
To try this, you should first fit the data in the DEMO1.QDP file
to a CO LI QU model,
as described in the previous section.
Now enter the command
PLT> Uncertain 1
The program will now change the value of parameter 1 by a small amount
and recompute c2.
At each step,
the delta parameter value and the Dc2 are printed out.
For complicated models it may take many steps
before the desired value of Dc2 is found.
The program considers both positive and negative delta parameter values.
The default value of Dc2 is 2.7
which corresponds to the 90% confidence range for a single parameter.
With the DEMO1.QDP file you will find
that both parameter 1 and 2 are consistent with zero.
To see if they can be eliminated, try the following:
PLT> Newpar 1,0,-1
PLT> Newpar 2,0,-1
PLT> Fit
The first command resets both the VAL and SIG terms
of parameter 1 to be 0.0 and -1.0, respectively.
A SIG of -1.0 means that the parameter is frozen
and hence not allowed to change.
Note: The command Newpar 1,,-1 would have frozen parameter 1 at its current value.
The second line freezes the value of parameter 2 to be zero.
The results of the Fit reveal that c2
has increased by 0.55 and the F-statistic
or a likelihood ratio tells us
that these two components were not required by the model.
The Uncertainty command is fairly robust
but on occasion can have difficulties.
Sometimes, Uncertainty will find a new minimum value of c2.
This causes the search to be stopped
and the parameter values to be reset.
At this point, you should reissue the Fit command
to locate precisely the new minimum.
Sometimes, Uncertainty will be unable
to locate the requested value of Dc2 after 10 tries.
At this point the message UNCERT-Give up. is printed.
It will be up to you to decide if the error has been correctly calculated.
Finally, the Uncertainty command
uses the SIG value to estimate the location of the error.
If this number is greatly in error,
then Uncertainty will be start it's search in the wrong place.
If this occurs then it is sometimes possible to adjust SIG
to be a more accurate estimate,
before issuing the Uncertainty command.
It is also possible that the SIG is inaccurate because the
true minimum has not been found and further fitting is needed.