NAME dsdlcurve -- reads heao1 scanning data and creates scan files centered at chosen targets using selected scalar rates from the MED and HED3 detectors.
equinox ra dec infile rootname beta ivwoff daily_effic iclwt1 sc_mode sc_wt1 sc_wt2 sc_wt3 sc_wt4 sc_wt5 sc_wt6 sc_wt7 sc_wt8 det_select det_no anti_coeff anti_mode anti_wt (tchat) (lchat) (clobber) (mode)
This program accumulates scanning profiles in the vicinity of a given object's position, and indicates the times when the source was in view. It uses the DSDISK data which consists of two files: one for the large (3.0 x 3.0 degree) and one for the small (1.5 x 3.0 degree) field of view (FOV). Each file includes counts only for the HED3 and MED detectors (part of the HEAO1 A2 experiment) in four energy bands (known as discovery scalars) taken during the mission lifetime. DSDLCURVE processes only one file at a time either for the small or for the large FOV. For a selected time period and "discovery scalars", DSDLCURVE accumulates data every 25 degrees scan angle during times when the source is in the experiment's field of view (FOV). The DSDLCURVE output contains count rate as a function of scan angles. The DSDDISK data are available from the HEASARC HEAO1 ftp area
"0" 1st 6 month scan of the experiment (day 232.1 - day 454.9). "1" 2nd 6 month scan of the experiment (day 400.1 - day 614.6). "2" 3rd 6 month scan of the experiment (day ? - day 737.1).
0 use default values for total rate 1 use default values for hard rate 2 use default values for soft rate 3 use default values for R15 rate 4 use default values for WTD R15 rate 5 use default values for MED M1 rate 6 to enter values from keyboard
It is strongly advised that the user choose the pre-defined values for the desired option (these values are tabulated in the appendix of the HEAO1 data analysis User Guide and are provided on the HEAO1 Software WWW page). If the user chooses option 6 to enter values from the keyboard the program will prompt for the Discovery Scalar mode, and the weights for each color. If options 0-5 are chosen these parameters are skipped.
MODE 1: HD3 M1,M2,-,- MED M1,-,-,- MODE 2: HD3 M1,M2,-,- MED M1,M2,-,- MODE 3: HD3 M1,M2,-,- MED 1ACD,1B,2A,2B MODE 4: HD3 1AD,1B,1C,M2 MED 1ACD,1B,2A,2B MODE 5: HD3 1A,1B,1CD,M2 MED 1ACD,1B,2A,2B MODE 6: HD3 1A,1B,1CD,M2 MED 1A,1B,1CD,M2
Each mode possesses up to 8 colors. Weights may be applied to the colors as desired. You should choose the weights such that each mode produces approximately the same summed rate.
None known