XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


swcx (esas-0.10.5) [xmmsas_20190531_1155-18.0.0]

Parameters

This section documents the parameters recognized by this task (if any).

ParameterMand Type Default Constraints
prefixyesstring  
Detector and exposure identifiers (eg. "1S001") for the MOS exposure S001) to be processed.
 
caldbyesstring  
Directory containing all the ESAS specific calibration files
 
ccd[1-7]yesstring1 
Flag to include (1) or not (0) a CCD.
 
elowyesint400 
The low energy for the band in eV
 
ehighyesint1300 
The high energy for the band in eV
 
elinelistyesunknown1 2 
Energies of SWCX lines to be included
 
gnormlistyesunknown0.1 0.03 
Gaussian normalizations from Xspec
 
objrmfyesstring  
RMF for the region
 
objarfyesstring  
ARF for the region
 
objspecyesstring  
Spectrum for the region
 
clobbernobooleanyesT/F
Clobber existing files?
 
ParameterMand Type Default Constraints

XMM-Newton SOC/SSC -- 2019-06-02