eqwidth
determine equivalent width
Determine the equivalent width of a model component.
Syntax: eqwidth [[range <frac range>] [<model name>:]<model component number>]
[err <number><level>|noerr]
The command calculates the integrated photon flux produced by an additive
model component (combined with its multiplicative and/or convolution
pre-factors) (FLUX), the location of the peak of the photon spectrum (E),
and the flux (photons per keV) at that energy of the continuum (CONTIN).
The equivalent width is then defined as {EW = FLUX / CONTIN} in units of
keV. New for XSPEC12: the continuum is defined to be the contribution
from all other components of the model.
There are certain models with a lot of structure where, were they the
continuum, it might be inappropriate to estimate the continuum flux at a
single energy. The continuum model is integrated (from
to
. The initial value of <frac range> is 0.05
and it can changed using the range keyword.
The err/noerr switch sets whether errors will be estimated on
the equivalent width. The error algorithm is to draw parameter values from
the distribution and calculate an equivalent width. <number> of sets
of parameter values will be drawn. The resulting equivalent widths are
ordered and the central <level> percent selected to give the error
range. You can get the full array of simulated equivalent width values
by calling tclout eqwidth with the errsims option
(see tclout command).
When Monte Carlo Markov Chains are loaded (see chain command), they
will provide the distribution of parameter values for the error estimate.
Otherwise the parameter values distribution is assumed to be a
multivariate Gaussian centered on the best-fit parameters with sigmas from
the covariance matrix. This is only an approximation in the case that
fit statistic space is not quadratic.
Examples:
The current model is assumed to be
, where the
models are multiplicative and the models are additive.
XSPEC12> eqwidth 3
// Calculate the total flux of component M1A2 (the third
// component of the model with its multiplicative pre-factor)
// and find its peak energy (E). The continuum flux is
// found by the integral flux of M1(A1+A3+A4+M2(A5)), using the
// range of 0.95E to 1.05E to estimate the flux.
XSPEC12> eqwidth range .1 3
// As before, but now the continuum is estimated from
// its behavior over the range 0.9E to 1.1E.
XSPEC12> eqwidth range 0 3
// Now the continuum at the single energy range (E)
// will be used.
XSPEC12> eqwidth range .05 2
// Now the component M1A1 is used as the feature, and
// M1(A2+A3+A4+M2(A5)) are used for the continuum. The range
// has been reset to the original value.
XSPEC12> eqwidth 1
// Illegal, as M1 is not an additive component.
HEASARC Home |
Observatories |
Archive |
Calibration |
Software |
Tools |
Students/Teachers/Public
Last modified: Friday, 23-Aug-2024 13:20:40 EDT
HEASARC Staff Scientist Position - Applications are now being accepted for a Staff Scientist with significant experience and interest in the technical aspects of astrophysics research, to work in the High Energy Astrophysics Science Archive Research Center (HEASARC) at NASA Goddard Space Flight Center (GSFC) in Greenbelt, MD. Refer to the AAS Job register for full details.
|