WebPIMMS Help
WebPIMMS is a Web interface to the command-line version of
PIMMS. As such, it incorporates many of the features and all of the
limitations of PIMMS. For information about PIMMS, or more detailed
information about what WebPIMMS does, the user should look at the
PIMMS User Guide.
Note:This guide is written for the new version of
WebPIMMS. Some features may not be available in the old WebPIMMS.
The input source is selected here.
- Flux/Unabsorbed Flux - input is an energy range in keV or Angstroms, not folded through any instrument.
- FDensity - Flux Density at a single energy in ERGS (No Range Should Be Entered, and Photons is not an option at this point).
Input Energy Range is a required field with these selections.
- ASCA/SIS Count Rate - input is the count rate from the ASCA SIS.
The default energy is in the 0.3-12 keV range.
- ASCA/GIS Count Rate - input is the count rate from the ASCA GIS.
The default energy is in the 0.4-12 keV range.
- Chandra HRC Count Rate - input is the count rate from the Chandra HRC.
The default energy is in the 0.1-10 keV range.
- Chandra ACIS Count Rate - input is the count rate from the Chandra ACIS.
The default energy is in the 0.1-10 keV range.
- CGRO/OSSE Count Rate - input is the count rate from the CGRO OSSE.
The default energy is in the 55-9190 keV range.
- Einstein/HRI Count Rate - input is the count rate from the Einstein HRI.
The default energy is in the 0.1-6 keV range.
- Einstein/IPC Count Rate - input is the count rate from the Einstein IPC.
The default energy is in the 0.1-6.4 keV range.
- Exosat/GSPC Count Rate - input is the count rate from the Exosat GSPC.
The default energy is in the 1-31 keV range.
- Exosat/ME Count Rate - input is the count rate from the Exosat ME.
The default energy is in the 0.4-36 keV range.
- GINGA/LAC Count Rate - input is the count rate from the GINGA LAC.
The default energy is in the 1-70 keV range.
- ROSAT/HRI Count Rate - input is the count rate from the ROSAT HRI.
The default energy is in the 0.1-2.4 keV range.
- ROSAT/PSPC Count Rate - input is the count rate from the ROSAT PSPC.
The default energy is in the 0.08-2.9 keV range.
- RXTE/ASM Count Rate - input is the count rate from the RXTE ASM.
The default energy is in the 1-12 keV range.
- RXTE/PCA Count Rate - input is the count rate from the RXTE PCA.
The default energy is in the 1.4-100 keV range.
- RXTE/HEXTE Count Rate - input is the count rate from the RXTE HEXTE Default.
The default energy is in the 10.1-552 keV range.
- RXTE/HEXTE Count Rate - input is the count rate from the RXTE PDS.
The default energy is in the 10.2-552 keV range.
- SAX/LECS Count Rate - input is the count rate from the SAX LECS.
The default energy is in the 0.1-14 keV range.
- SAX/MECS Count Rate - input is the count rate from the SAX MECS.
The default energy is in the 0.8-12 keV range.
- SAX/PDS Count Rate - input is the count rate from the SAX PDS.
The default energy is in the 7-477 keV range.
- SWIFT/BAT - input is the count rate from the SWIFT BAT Onaxis.
The default energy is in the 15-150 keV range.
- SWIFT/XRT - input is the count rate from the SWIFT XRT Onaxis.
The default energy is in the 0.2-10 keV range.
- SWIFT/1to4 - input is the count rate from the SWIFT 1to4 Onaxis.
The default energy is in the 0.2-10 keV range.
- SWIFT/UVOT - input is the count rate from the SWIFT UVOT.
The default energy is in the 0.01-0.1 keV range.
- XMM/RGS Count Rate - input is the count rate from the XMM RGS Order1.
The default energy is in the 0.3-2.5 keV range.
- XMM/MOS Count Rate - input is the count rate from the XMM MOS Open.
The default energy is in the 0.1-12 keV range.
- XMM/PN Count Rate - input is the count rate from the XMM PN Open.
The default energy is in the 0.1-12 keV range.
The output mission/energy is selected here.
In the new WebPIMMS all the instruments are selected. In the old WebPIMMS
you can choose the instruments you want to calculate.
- ASCA - output is the ASCA count rate calculated from the input source.
- SUZAKU - output is the SUZAKU count rate calculated from the input source.
- CHANDRA - (AXAF) output is the CHANDRA count rate calculated from the input source.
- INTEGRAL - output is the INTEGRAL count rate calculated from the input source.
- ROSAT - output is the ROSAT count rate calculated from the input source.
- RXTE - output is the RXTE count rate calculated from the input source.
- SAX - output is the SAX count rate calculated from the input source.
- Swift - output is the SAX count rate calculated from the input source.
The BAT response in PIMMS v3.6c and later yields the counts
per fully illuminated detector, which matches the BAT analysis software
default units. One detector has a geometric area of 0.16
cm2. An on-axis source illuminates 16384 detectors
- XEUS - output is the XEUS count rate calculated from the input source. Note: Observation efficiency is expected to be ~30%
- XMM - output is the XMM count rate calculated from the input source.
For the RGS, the default energy ranges are:
Order 1: 0.35 - 2.5 keV
Order 2: 0.62 - 2.5 keV
Order 3: 1.20 - 2.5 keV
- Flux - output is in flux, not folded through any instrument in ergs/cm2/s. Output Energy Range is a required field with this selection.
Specifies the spectral shape to be folded with the effective area curve of
the instrument. Currently four simple, one-parameter models plus a gaussian
are recognized with a fixed absorption model (due to Morrison &
McCammon).
- Power Law - Parameter is photon index.
(Flux in photons/cm2/s is E[-(index)]).
A power-law photon spectrum that increases with increasing energy can be specified by entering a negative number as the index.
- Black Body - Parameter is temperature (keV).
- Therm. Bremss. - Parameter is temperature (keV).
The model includes the Gaunt factor.
- Raymond-Smith - Parameter is plasma temperature (keV).
WebPIMMS uses one of 59 pre-calculated models (see pull-down menu) that cover a range of values between 0.0343 keV - 27.25 keV.
Note: If a different value is entered WebPIMMS uses the closest allowed value. Abundance is assumed to be Solar, as defined by Allen.
Additional Raymond-Smith Model Selection The user also has the option of selecting a Solar Abundance fraction and a Log T. If these values are set, they will override the keV entered previously.
- Gaussian - Parameters are:
- line center energy (kev);
- line width (kev);
- equivalent width relative to base model (eV).
This model takes the central energy and physical width (in keV) as
parameters. A physical width of 0 is allowed, which is interpreted as
a delta function (integrations of the delta function is treated
appropriately, although it may look incorrect in the differential
form, which is what is saved by the OUTPUT command).
Note:Gaussian is primarily intended as a second (etc.) component in addition to a
continuum model, with the same nH as the primary component. In such cases,
specify the equivalent width in eV rather than the 'relative strength'
Up to 3 model components can be added together to represent
multi-temperature plasma, power law plus Gaussian emission line,
partial-covering absorber etc. Only a limited combinations of models have
been rigorously tested. When selecting multiple models, in addition to the
standard model parameters, the user needs to input:
- Normalization - Always relative to the base model. NOT equivalent to the XSPEC normalization
- Energy - At which the models are normalized (keV).
- Input Energy Range - When a specific mission is
selected (i.e. ASCA, RXTE...) the user can specify the energy range of
the satellite response to be used in the calculations. If left BLANK,
or UNCHANGED from the default value, it uses the instrument default
values.
- When 'Flux' or 'Unabsorbed Flux' is selected, the energy range of the
source MUST be set by the user. The model will then be integrated over the specified range.
This can be entered in either keV or Angstroms by selecting the appropriate unit.
- When 'Flux Density' is selected, a SINGLE energy value MUST be set by
the user. The input value is then taken to be the model flux per unit energy or per unit
wavelength, as appropriate. This can be entered in either keV or Angstroms by
selecting the appropriate unit.
- Output Energy Range - When a specific mission is
selected (i.e. ASCA, RXTE...) the user can specify the energy range of
the satellite response to be used in the calculations. If left BLANK,
or UNCHANGED from the default value, it uses the instrument default
values.
-When 'Flux' is selected in "Into" WebPIMMS will convert the input
source value into energy (ergs/cm2/s). The energy range of
the source MUST be set by the user. Both absorbed and unabsorbed flux
(nH = 0) are calculated simultaneously. This can be entered
in either keV or Angstroms by selecting the appropriate unit.
Values pertaining to the source.
- Flux/Count Rate - The source energy. If the user
is converting from 'Flux' the units are (erg/cm2/s), if
converting from a mission, the units are (counts/second) for that
mission.
- Galactic NH - The neutral Hydrogen column
density, within the Milky Way, along the line-of-sight to the source.
Refer to the HEASARC's NH Tool.
PIMMS does NOT allow for a decimal exponent to be entered, and will
give an erroneous answer if used.
- Photon Index/kT - The model-dependent
parameter. If the 'Power Law' model is selected then value is the
photon index, i.e [E^-(index)], for all other models the value is
temperature in keV.
Optionally, all components may be redshifted using a common z; in which
case, all optional nH values are interpreted as an intrinsic
absorber with the same z, in addition to the required Galactic
NH.
Go back to the PIMMS Web interface.
Go back to the Multi-component/Gaussian
PIMMS Web interface.
For help in the use of PIMMS, see the
PIMMS User Guide
WebPIMMS is a Web version of the
PIMMS tool.
PIMMS was developed by Koji
Mukai at the HEASARC. The first Web version was developed at the
SAX Data Center. The SAX PIMMS
package was ported to and modified for the HEASARC Web site by Michael Arida.
The Web front-end interface was developed by Edward J. Sabol.
This file was last modified on Thursday, 11-Jul-2024 12:05:56 EDT
For feedback or questions on WebPIMMS, please contact Michael Arida.
HEASARC Home |
Observatories |
Archive |
Calibration |
Software |
Tools |
Students/Teachers/Public
HEASARC Staff Scientist Position - Applications are now being accepted for a Staff Scientist with significant experience and interest in the technical aspects of astrophysics research, to work in the High Energy Astrophysics Science Archive Research Center (HEASARC) at NASA Goddard Space Flight Center (GSFC) in Greenbelt, MD. Refer to the AAS Job register for full details.
|